Eko Coal - CAST IRON SOLID FUEL BOILERS
PDF Download: Eko Coal Brochure
Characteristristics:
- Thermostatic draught control that governs insertion of air under the grille.
- Secondary air control
- Flue draught control
- Boiler temperature thermometer
Main characteristics:
- High combustion performance
- Excellent resistance to corrosive agents
- Combustion chamber of a regular shape to ensure maximum fuel load
Ease of loading and autonomous operating time: 
- Spacious fire box to increase autonomous operating time
- Spacious loading door
- Lever for loading door opening with an anti-burn soft rubber protection
Optimized combustion:
- Designed to ensure uniform thermal load
- Distribution of secondary air with pre-heating
- Bathed and finned grille
- Fire box with spacers between load and walls
- Rear element with rungs on a fire side and intermediate elements
Smoke path in three sections:
- Uniform air entry under combustion grille
- Less thermal stress
- Distribution of unburned residues
Three burning stages
- Stage1
The combustion by-products are carried by a special passage obtained in the rear element. In the same area, very hot secondary air is inserted which favours complete oxidation of the gases.
- Stage2
Gases from the rear element are sent to a wide-finned, self-cleaning zone, in the same time they make a favour entry into the third section.
- Stage3
The third section directs the smoke towards the
flue with adjustment shutter and door for cleaning.

Eko Coal - CAST IRON SOLID FUEL BOILERS - technical data`
Description |
Unit of measure |
Eko Coal21 |
Eko Coal26 |
Eko Coal 31 |
Eko Coal 36 |
| Fuel |
|
Coal |
| Negative pressure at flue (Min / Max) |
mbar |
0.1/0.3 |
| Maximum acceptable temperature |
oC |
95 |
| Operating temperature (range) |
oC |
40÷90 |
| Minimum permissible return temperature |
oC |
50
|
| "PMS" maximum operating pressure |
bar |
|
| Duration of one load |
h |
>2 |
| Diameter of flue fitting |
mm |
180 |
| Unit class* |
no. |
1 |
| Water side pressure drop (D t= 150C) |
mbar |
12 |
15 |
18 |
20 |
| Water side pressure drop (D t= 200C) |
mbar |
10 |
12 |
14 |
17 |
| Water capacity in a boiler |
l |
35 |
41 |
47 |
53 |
Dimensions:
Model |
Number of elements |
Nominal average
thermal power (Qn)
kW |
Dimensions of door W x H
cm |
Dimen. of chamber
WxHxD
cm |
Volume of
loading /
combustion
chamber
l |
Dimensions (mm) |
Weight (kg) |
Height (mm) |
Width (mm) |
Depth (mm) |
| Eko Coal21 |
4 |
21,2 |
38 x 30 |
38 x 43 x 34 |
55 |
955 |
600 |
525 |
270 |
| Eko Coal26 |
5 |
26,2 |
38 x 30 |
38 x 43 x 45 |
73 |
955 |
600 |
635 |
315 |
| Eko Coal31 |
6 |
30,5 |
38 x 30 |
38 x 43 x 56 |
91 |
955 |
600 |
745 |
365 |
| Eko Coal36 |
7 |
35,2 |
38 x 30 |
38 x 43 x 67 |
109 |
955 |
600 |
855 |
410 |
Diagrams:
- Direct connection to centraol heating plants (.pdf)
- With energy accumulator to supply the central heating plants (.pdf)
- In conjunction with another boiler, with energy accumulator (.pdf)